Gira Basic Q smoke alarm device

Safe through scattered light measurement - now with Q quality seal

The Gira Basic Q smoke alarm device can save lives. It automatically detects dangerous accumulations of smoke and sounds the alarm with a loud, pulsing alarm tone (85 dB) and a red LED ring indicator. In doing so, it utilises the photoelectric scattered-light principle: Smoke, which develops during fires, contains fine smoke particles. The density of these smoke particles is measured by the smoke alarm device. A diode in the device continuously emits light signals, and a photo cell analyses the scattered light caused by smoke particles.

An alarm is triggered as soon as the concentration of scattered light exceeds the limit. With its high-quality design, the Gira Basic Q smoke alarm device blends in well with any surroundings. The device has an integrated battery with a service life of at least 10 years. Its cost-effective nature makes it easy to take precautions against damage caused by fire in every room.

  • Q seal for enhanced quality
  • Visual alarm via a red LED ring indicator
  • Button for function test
  • Battery failure warning (30 days)
  • Detection of smoke through scattered light measurement
  • Acoustic alarm with a loud, pulsating tone
  • Battery life of at least 10 years
  • Reduction in the number of false alarms

Q seal for enhanced quality

Awarded the Q seal, the Gira Basic Q smoke alarm device fulfils increased quality criteria according to the vfdb guideline 14-01 and DIN EN 14604:2009-02. The Q seal stands for certified long service life and the reduction of false alarms with simultaneously increased stability, e.g. against external factors.

More about the Q quality seal


Detection of smoke through scattered light measurement

The Gira Basic Q smoke alarm device detects fires at an early stage from the build-up of smoke. To do this, it uses the photoelectric scattered-light principle: A diode in the device continuously emits light signals to detect smoke, and a photo cell analyses the scattered light caused by smoke particles. An alarm is triggered as soon as the concentration of scattered light exceeds the limit.


Battery failure warning (30 days)

The Gira Basic Q smoke alarm device continuously monitors its smoke analysis and checks the battery voltage. Any faults are indicated by a fault signal (signal tone and LED). The Gira Basic Q smoke alarm device signals that the device will have to be replaced 30 days in advance. The device remains completely functional during this period.


Installation locations

There should be smoke alarm devices in the hallway and staircase, as well as in each bedroom and children’s room. In buildings with several floors, there should be at least one smoke alarm device on each floor. This increases the safety of all the occupants of the building. Note: In the kitchen, the Gira Basic Q smoke alarm device should be installed as far from the cooking area as possible in order to prevent false alarms caused by water vapour.


Certified safety: Recommendation for the installation of smoke alarm devices

Smoke alarm devices are lifesavers – and must therefore be able to do their job reliably in case of an emergency. For this reason, you must ensure that they are correctly installed. In order to ensure that smoke alarm detectors are professionally installed in accordance with DIN 14676, the standard provides recommendations for verifying the professional competence of service providers performing the planning, installation and maintenance of such devices.

‘Gira smoke alarm device’ online distance learning course


Mandatory installation of smoke alarm devices

400 fire deaths, 4,000 burn victims with long-term damage and more than a billion euros of fire damage in the private sector every year – in most cases, a smoke alarm device could have saved lives, because far more than half of all fire victims are caught unaware while asleep at night. Nowadays, Germany has implemented a nationwide regulation requiring the installation of smoke alarm devices. This means that all new builds and conversions at least must be equipped with suitable smoke alarm devices in bedrooms, children’s rooms, and hallways that are used as rescue routes leading outdoors. In some cases, various transitional regulations apply to existing residences. They must then also be equipped accordingly.


Installation instructions

The Gira Basic Q smoke alarm device has a flat design which enables easy installation. The battery-operated device requires no wire connections and functions optimally when it is mounted under the ceiling in the middle of the room. Where smoke alarm devices should be positioned to guarantee minimum protection varies depending on the design of the house or apartment. In single-story apartments, the hallway used most frequently in case of fire should be part of the minimum configuration. In multi-story buildings, the hallways of each story must be included. However, it is advisable to equip all rooms for optimum protection.


Technical data

Power supply:
permanently installed battery
Battery:
9-V lithium block battery with service life of at least 10 years
Acoustic alarm signal:
pulsating sound of at least 85 dB (A)
Optical alarm display:
Light ring with red LED
Dimensions:
Ø 125 x H 38.5 mm
Installation height:
max. 4.50 m
Plastic material:
PC-ASA
Operating temperature:
-5 °C to +55 °C
Storage temperature:
-20 °C to +65 °C
Weight:
approx. 240 g
Protection type:
IP 42
Application range:
According to DIN 14676
Approval according to:
DIN EN 14604

Design/awards

Product design
Gira Design Team, Radevormwald

Download

Operating instructions

Smoke alarm device Dual Q

Installation and operating instructions

Bestell-Nr 2336 02, 2346 02

PDF, 270,1 KB

Download

Technical Documentation

The following files are not available in the language you have selected, but may be in other translations.

Wartungshandbuch für Rauchwarnmelder Q

Inbetriebnahme / Wartung durch die Fachkraft für Rauchwarnmelder Q gemäß DIN 14676

Bestell-Nr 2336 02, 2346 02, 1145 02, 1149 02, 2333 00

PDF, 1,0 MB

Download

Back to top Download