back

Order No. 0529 00, 2075 00

ZIP, 458.819 Kb

Version: 4.11.0

Date: 07.12.2020

Download

Experte Version 4.11.0

System requirements

  • Operating system: Windows 7, Windows 8, Windows 10
  • Free hard drive space: at least 1 GB
  • RAM: at least 2 GB
  • Software platform: at least Microsoft .NET 4.5

Supported devices

The Expert Software 4.11.0 is to be used in conjunction with the following end devices:

  • Gira HomeServer 4
  • Gira FacilityServer 4

Update information

It is only possible to update to firmware version 4.11.0 from the following version:

  • 4.10.1.200330
  • 4.10.0.200117
  • 4.9.0.190612

New products and improvements

Expert/firmware

  • Logic online test in the graphical logic editor
  • Simplification of the configuration
  • Connection to Gira Alarm Connect
  • DHCP
    DHCP can be set under the project settings / network.
  • Revised scene node
  • Home page
    An overview page with all the available URL call-ups is now displayed when the IP address of the HomeServer is entered.

QuadClient

  • Day/night switch-over
    The QuadClient can be switched between day (bright design) and night (dark design).
  • New symbols
  • Floor plan navigation
  • Floor plan editor
  • Alarm plug-in

Bug fixes

  • Project transfer dialogue not always in the background
  • Scenes logic node - faulty translation fixed
  • Expert - no error message after project import to missing HSLX files
  • Expert - error message issued if “forbidden” port has been set
  • Expert - images/symbols from global library are not displayed correctly or are mixed up in Design 1920x1080V
  • The error has been fixed in version 4.11.0. However, if a global library of an older expert version is imported, the error may reoccur because the global libraries of the older version are also affected by the error.
  • Expert - visualisation of dynamic texts - if “Call up last settings” is not set, the dialogue is shown again in the visualisation when setting up dynamic texts.
  • Expert - visualisation - “smaller than” character “<” is no longer displayed as “[”.
  • HS Client - GIFs were not able to be selected in the HS Client under certain circumstances (error fixed)
  • Logic node - “selector switch” input - error at input 2 fixed
  • QuadClient - weather forecast plug-in - refresh within specified time again
  • QuadClient - template definition in Design 5, centred display adapted for iOS
  • QuadClient - the return times for MyTouch are now permanently applied
  • QuadClient - function template Push-button Plus (ID 1-118) with PIN protection adapted
  • QuadClient - timer in QC Dimming Plus adapted

Known errors

  • DCS communicator - Show and Hide commands under Windows 10
  • HomeServer / S1 - camera access from external point does not work correctly
  • HS QC call-up from specific tab via menu item does not work
  • Logic node: “Evaluate forwarding status”
  • S1 Windows Client - HS free visualisation call-up in browser - the certificate is not recognised
  • QC configuration - umlauts in the user name